Standard Plumbing Supply
Robertshaw 780-845 Ignition Module, Intermittent Pilot, 24V
See current price

See current price
Check the current price and availability on Amazon.com.
View on AmazonAffiliate link — we may earn a commission at no extra cost to you. Learn more
| Manufacturer | Standard Plumbing Supply |
|---|---|
| Part Number | 780-845 |
| Item Weight | 14.4 ounces |
| Product Dimensions | 4.75 x 1.5 x 3 inches |
| Item model number | 780-845 |
| Thickness | 1 Inches |
| Voltage | 24 Volts |
| Item Package Quantity | 1 |
| Included Components | Product & Instructions Guide |
| Batteries Included? | No |
| Batteries Required? | No |
| ASIN | B0028UHBS4 |
When the thermostat calls for heat, the 780-845 control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve. Pilot flame recognition stops ignition sparking and opens the main valve portion of the gas valve. Pilot burner flame is continuously monitored at a synchronous frequency for the duration of the heating cycle. Should the pilot flame fail during the heating cycle, the control will shut off the main valve until the pilot flame is established. The 780-845 lockout ignition control provides 90 seconds of spark, followed by a 6 minute time delay [purge] between ignition attempts. After three tries, if no pilot flame is sensed, the control goes into a one-hour lockout period. At the end of the lockout period, if the demand for heat is still present, the unit will repeat the three tries for ignition.