K-Catalog
Siemens QF215 15-Amp Double Pole 120/240-Volt type QPF Ground Fault Circuit Interrupter (Discontinued by Manufacturer)
  • Siemens QF215 15-Amp Double Pole 120/240-Volt type QPF Ground Fault Circuit Interrupter (Discontinued by Manufacturer)
  • Siemens QF215 15-Amp Double Pole 120/240-Volt type QPF Ground Fault Circuit Interrupter (Discontinued by Manufacturer)
  • Siemens QF215 15-Amp Double Pole 120/240-Volt type QPF Ground Fault Circuit Interrupter (Discontinued by Manufacturer)
SIEMENS

Siemens QF215 15-Amp Double Pole 120/240-Volt type QPF Ground Fault Circuit Interrupter (Discontinued by Manufacturer)

See current price

Check the current price and availability on Amazon.com.

View on Amazon

Affiliate link — we may earn a commission at no extra cost to you. Learn more

Current Rating
60 Amps
Voltage
240 Volts
Item Dimensions LxWxH
3 x 6 x 3 inches
Circuit Breaker Type
GFCI

Key features

  • This item is discontinued, a newer model is available (model QF215A)
  • 10 KAIC rated
  • Ground fault circuit interrupter
  • UL Type QPF breaker

Specifications

BrandSIEMENS
Current Rating60 Amps
Voltage240 Volts
Item Dimensions LxWxH3 x 6 x 3 inches
Circuit Breaker TypeGFCI
Mounting TypePlug-In Mount
Number Of Poles2
ManufacturerSiemens -HI
Part NumberQF215
Item Weight0.01 ounces
Product Dimensions3 x 6 x 3 inches
Item model numberQF215
ColorBlack
Style15-Amp
Item Package Quantity1
Included ComponentsSIEQF215
Batteries Included?No
Batteries Required?No
Warranty Description1 year manufacturer
ASINB00GPO9K7Y

About this product

Application GFCIs protect against electrical shock that result from ground faults. Ground faults occur when electrical current in devices stray outside of its normal path. A human body can become part of this circuit, which results in an electrical shock. GFCIs analyze the amount of current entering and existing from the circuit and will trip when the difference is greater than a certain value. Single Pole GFCI View larger Single Pole OfferingSingle Pole Wiring Schematic Double Pole GFCI View larger Double Pole OfferingDouble Pole Wiring Schematic Siemens GFCI circuit breakers are UL Listed and CSA Certified as Class A devices. Current imbalances of 4-6 milliamps or more between load conductors will cause the ground fault sensor to trip the circuit Breaker. Note: A load neutral is not required on the circuit. However, the white line neutral (pigtail) must be connected to the panel neutral for the device to function. The Siemens 2-pole GFCI circuit breaker can be installed on a 120/240-volt AC single phase, 3-wire system, the 120/240-volt AC portion of a 240/120-volt, 3-phase, 4-wire system, or on a 208Y/120-volt, 3-phase, 4-wire system. When installed on these systems, protection is provided for 2-wire, 240-volt AC or 208-volt AC circuits; 3-wire, 120/240-volt AC circuits. The Siemens 1-pole GFCI circuit breaker is to be installed only on a single phase 120/240-volt AC system. Features / Ratings Available in 1-pole (15-30 amps) and 2-pole (15-60 amps) through 60 amp rating Available in 1-pole (15-30 amps) and 2-pole (15-60 amps) through 60 amp rating Available in 10 kA and 22 kA ("H") interrupting rating Available in 10 kA and 22 kA ("H") interrupting rating Suitable for a variety of construction applications: spas, hot tubs, kitchens, bathrooms, etc. Suitable for a variety of construction applications: spas, hot tubs, kitchens, bathrooms, etc. Resists false tripping (shielded to prevent RF interference) Resists false tripping (shielded to prevent RF interference) Standard 1 inch per pole format with plug-in design Standard 1 inch per pole format with plug-in design UL Listed and CSA Certified UL Listed and CSA Certified Also available in BLF type (low tab bolt-on) Also available in BLF type (low tab bolt-on) Provides Class A GFCI protection Provides Class A GFCI protection HACR rated HACR rated

Similar products

See current price

View on Amazon